This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0.  For a full list of available versions, see the Directory of published versions  . Page versions: R4B R4 R3
. Page versions: R4B R4 R3
| Security  Work Group | Maturity Level: 3 | Trial Use | Use Context: Any | 
This is a value set defined by the FHIR project.
Summary
| Defining URL: | http://hl7.org/fhir/ValueSet/object-lifecycle-events | 
| Name: | ObjectLifecycleEvents | 
| Definition: | This example FHIR value set is comprised of lifecycle event codes. The FHIR Actor value set is based on DICOM Audit Message, ParticipantObjectDataLifeCycle; ISO Standard, TS 21089-2017; | 
| Committee: | ?? | 
| OID: | (for OID based terminology systems) | 
| Copyright: | This is an example FHIR value set based on ASTM Standard, E1762-95 (2013) HL7 RoleClass OID 2.16.840.1.113883.5.110, HL7 Role Code 2.16.840.1.113883.5.111, HL7 ParticipationType OID: 2.16.840.1.113883.5.90, HL7 ParticipationFunction codes at OID: 2.16.840.1.113883.5.88, and HL7 Security and Privacy Domain Analysis Model roles classes. These codes are excerpted from Digital Imaging and Communications in Medicine (DICOM) Standard, Part 16: Content Mapping Resource, Copyright © 2011 by the National Electrical Manufacturers Association. | 
| Source Resource | XML / JSON | 
This value set is used in the following places:
This value set includes codes from the following code systems:
http://hl7.org/fhir/dicom-audit-lifecyclehttp://hl7.org/fhir/iso-21089-lifecycle
This expansion generated 19 Apr 2017
This value set contains 40 concepts
Expansion based on http://hl7.org/fhir/dicom-audit-lifecycle version 20100826
| Code | System | Display | Definition | 
| 1 | http://hl7.org/fhir/dicom-audit-lifecycle | Origination / Creation | |
| 2 | http://hl7.org/fhir/dicom-audit-lifecycle | Import / Copy | |
| 3 | http://hl7.org/fhir/dicom-audit-lifecycle | Amendment | |
| 4 | http://hl7.org/fhir/dicom-audit-lifecycle | Verification | |
| 5 | http://hl7.org/fhir/dicom-audit-lifecycle | Translation | |
| 6 | http://hl7.org/fhir/dicom-audit-lifecycle | Access / Use | |
| 7 | http://hl7.org/fhir/dicom-audit-lifecycle | De-identification | |
| 8 | http://hl7.org/fhir/dicom-audit-lifecycle | Aggregation / summarization / derivation | |
| 9 | http://hl7.org/fhir/dicom-audit-lifecycle | Report | |
| 10 | http://hl7.org/fhir/dicom-audit-lifecycle | Export | |
| 11 | http://hl7.org/fhir/dicom-audit-lifecycle | Disclosure | |
| 12 | http://hl7.org/fhir/dicom-audit-lifecycle | Receipt of disclosure | |
| 13 | http://hl7.org/fhir/dicom-audit-lifecycle | Archiving | |
| 14 | http://hl7.org/fhir/dicom-audit-lifecycle | Logical deletion | |
| 15 | http://hl7.org/fhir/dicom-audit-lifecycle | Permanent erasure / Physical destruction | |
| 2 | http://hl7.org/fhir/iso-21089-lifecycle | Amend (Update) - Lifeycle Event | occurs when an agent makes any change to record entry content currently residing in storage considered permanent (persistent) | 
| 14 | http://hl7.org/fhir/iso-21089-lifecycle | Archive - Lifeycle Event | occurs when an agent causes the system to create and move archive artifacts containing record entry content, typically to long-term offline storage | 
| 4 | http://hl7.org/fhir/iso-21089-lifecycle | Attest - Lifecycle Event | occurs when an agent causes the system to capture the agent’s digital signature (or equivalent indication) during formal validation of record entry content | 
| 27 | http://hl7.org/fhir/iso-21089-lifecycle | Decrypt - Lifecycle Event | occurs when an agent causes the system to decode record entry content from a cipher | 
| 10 | http://hl7.org/fhir/iso-21089-lifecycle | De-Identify (Anononymize) - Lifecycle Event | occurs when an agent causes the system to scrub record entry content to reduce the association between a set of identifying data and the data subject in a way that may or may not be reversible | 
| 17 | http://hl7.org/fhir/iso-21089-lifecycle | Deprecate - Lifecycle Event | occurs when an agent causes the system to tag record entry(ies) as obsolete, erroneous or untrustworthy, to warn against its future use | 
| 16 | http://hl7.org/fhir/iso-21089-lifecycle | Destroy/Delete - Lifecycle Event | occurs when an agent causes the system to permanently erase record entry content from the system | 
| 7 | http://hl7.org/fhir/iso-21089-lifecycle | Disclose - Lifecycle Event | occurs when an agent causes the system to release, transfer, provision access to, or otherwise divulge record entry content | 
| 26 | http://hl7.org/fhir/iso-21089-lifecycle | Encrypt - Lifecycle Event | occurs when an agent causes the system to encode record entry content in a cipher | 
| 13 | http://hl7.org/fhir/iso-21089-lifecycle | Extract - Lifecycle Event | occurs when an agent causes the system to selectively pull out a subset of record entry content, based on explicit criteria | 
| 21 | http://hl7.org/fhir/iso-21089-lifecycle | Link - Lifecycle Event | occurs when an agent causes the system to connect related record entries | 
| 19 | http://hl7.org/fhir/iso-21089-lifecycle | Merge - Lifecycle Event | occurs when an agent causes the system to combine or join content from two or more record entries, resulting in a single logical record entry | 
| 1 | http://hl7.org/fhir/iso-21089-lifecycle | Originate/Retain - Record Lifecyle Event | occurs when an agent causes the system to: a) initiate capture of potential record content, and b) incorporate that content into the storage considered a permanent part of the health record | 
| 11 | http://hl7.org/fhir/iso-21089-lifecycle | Pseudonymize - Lifecycle Event | occurs when an agent causes the system to remove record entry content to reduce the association between a set of identifying data and the data subject in a way that may be reversible | 
| 18 | http://hl7.org/fhir/iso-21089-lifecycle | Re-activate - Lifecycle Event | occurs when an agent causes the system to recreate or restore full status to record entries previously deleted or deprecated | 
| 9 | http://hl7.org/fhir/iso-21089-lifecycle | Receive/Retain - Lifecycle Event | occurs when an agent causes the system to: a) initiate capture of data content from elseware, and b) incorporate that content into the storage considered a permanent part of the health record | 
| 6 | http://hl7.org/fhir/iso-21089-lifecycle | Report (Output) - Lifecycle Event | occurs when an agent causes the system to produce and deliver record entry content in a particular form and manner | 
| 12 | http://hl7.org/fhir/iso-21089-lifecycle | Re-identify - Lifecycle Event | occurs when an agent causes the system to restore information to data that allows identification of information source and/or information subject | 
| 24 | http://hl7.org/fhir/iso-21089-lifecycle | Remove Legal Hold - Lifecycle Event | occurs when an agent causes the system to remove a tag or other cues for special access management had required to fulfill organizational policy under the legal doctrine of “duty to preserve†| 
| 15 | http://hl7.org/fhir/iso-21089-lifecycle | Restore - Lifecycle Event | occurs when an agent causes the system to recreate record entries and their content from a previous created archive artifact | 
| 3 | http://hl7.org/fhir/iso-21089-lifecycle | Transform/Translate - Lifecycle Event | occurs when an agent causes the system to change the form, language or code system used to represent record entry content | 
| 8 | http://hl7.org/fhir/iso-21089-lifecycle | Transmit - Lifecycle Event | occurs when an agent causes the system to send record entry content from one (EHR/PHR/other) system to another | 
| 22 | http://hl7.org/fhir/iso-21089-lifecycle | Unlink - Lifecycle Event | occurs when an agent causes the system to disconnect two or more record entries previously connected, rendering them separate (disconnected) again | 
| 20 | http://hl7.org/fhir/iso-21089-lifecycle | Unmerge - Lifecycle Event | occurs when an agent causes the system to reverse a previous record entry merge operation, rendering them separate again | 
| 25 | http://hl7.org/fhir/iso-21089-lifecycle | Verify - Lifecycle Event | occurs when an agent causes the system to confirm compliance of data or data objects with regulations, requirements, specifications, or other imposed conditions based on organizational policy | 
See the full registry of value sets defined as part of FHIR.
Explanation of the columns that may appear on this page:
| Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies | 
| Source | The source of the definition of the code (when the value set draws in codes defined elsewhere) | 
| Code | The code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract') | 
| Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application | 
| Definition | An explanation of the meaning of the concept | 
| Comments | Additional notes about how to use the code |